Find out by following
these steps:
1 ) Measure the DC voltages between (DB25) pins 2 & 7 and between pins 3 & 7. Be sure the black lead is connected to pin 7 (Signal Ground) and the red lead to whichever pin you are measuring.
2) If the voltage on pin 2 is more negative than -3 Volts, then it is a DTE, otherwise it should be near zero volts.
3) If the voltage on pin 3 is more negative than -3 Volts, then it is a DCE.
4) If both pins 2 & 3 have a voltage of at least 3 volts, then either you are measuring incorrectly, or your device is not a standard EIA-232 device. Call technical support.
5) In general, a DTE provides a voltage on TD, RTS, & DTR, whereas a DCE provides voltage on RD, CTS, DSR, & CD.